TM 10-3510-209-24
3-18. EXTRACTOR CONTROL BOX (CONT)
ADJUSTMENT (Cont)
4.
Adjust lid lock lever.
WARNING
High voltage is present on this equipment. Do not perform maintenance with
power on. Death or serious injury may result.
a.
Set extractor circuit breaker on electrical panel to the OFF position.
b.
Remove twelve screws (1), lockwashers (2), and extractor control panel cover (3).
c.
Loosen locknut (13) on the end of lid lock
lever (14).
d.
Rotate lid lock lever adjusting screw (15)
until it is within 1/16 inch (1.58 mm) of the
face on the lid lock cam (16). Tighten
locknut (13).
e.
Attempt to lift lid. Lid is properly adjusted
when gap between lid and curb is no more
than 1/2 inch (1.27 mm) when closed and
locked.
f.
Install extractor control panel cover (3),
twelve lockwashers (2), and screws (1).
g.
Turn extractor circuit breaker in power
panel to ON.
3-80