TM 10-3510-209-24
3-18. EXTRACTOR CONTROL BOX (CONT)
ADJUSTMENT (Cont)
b.
Remove twelve screws (1), lockwashers (2), and extractor control panel cover (3).
c.
Ensure lid (6) is closed.
d.
Loosen two solenoid screws (11) and slide solenoid safety switch (12) upward. A small amount of
adjustment is necessary to prevent sliding the switch upward too far and damaging the lid solenoid.
e.
Tighten safety switch screws (11).
WARNING
High Voltage is present on this
equipment. Use extreme caution
while power is on and control box
components are exposed.
f.
Connect power to the extractor.
g.
Start
the
extractor.
Refer
to
TM 10-3510-209-10.
h.
If the extractor motor fails to run, repeat
steps d thru g above.
i.
Turn off extractor.
j.
Install extractor control panel cover (3),
twelve lockwashers (2), and screws (1).
3-79