3-18. EXTRACTOR CONTROL BOX (CONT)
ADJUSTMENT (Cont)
f.
If lid safety switch (9) cannot be pressed, perform the following:
(1)
Loosen two screws (10) that secure lid safety switch (9).
(2)
Adjust lid safety switch (9) against lid safety cam (8) until switch is pressed.
(3)
Tighten two screws (10) securing lid safety switch (9).
(4)
Repeat steps e and f until safety switch (9) is pressed.
g.
Tighten lid safety cam screw (7).
h.
Install extractor control panel cover (3), twelve lockwashers (2), and screws (1). Set extractor circuit
breaker in power panel to the ON position.
WARNING
Keep clear of the extractor basket
when checking operation of the lid
safety switch.
i.
Open lid and try to start extractor to
ensure unit does not operate with lid open.
Refer to TM 10-3510-209-10.
3.
Adjust solenoid safety switch.
WARNING
High voltage is present on this
equipment.
Do
not
perform
maintenance with power on. Death
or serious injury may result.
WARNING
Failure to adjust the solenoid safety
switch properly could result in injury
to personnel.
a.
Set extractor circuit breaker on electrical
panel to the OFF position.
3-78