Table 2-2. Unit Troubleshooting (Continued)
MALFUNCTION
TEST OR INSPECTION
CORRECTIVE ACTION
34.
WASHER FILL LEVEL IS TOO LOW. (Cont)
(4) Position new high level switch (5) in switch box (3) and
install two screws (7).
(5) Connect wires (4) to high level switch (3) and remove tags.
(6) Install cover (2) and screw (1) on switch box (3).
NOTES:
CONDUIT AND
WIRES REMOVED
FROM SWITCH BOX
FOR CLARITY.
b.
If switch is serviceable, proceed to next step.
Step 4.
Check for clogged drain valve during filling and check for low drain
valve air supply (60 to 80 psi [414 to 552 kPa]).
a.
If drain valve is clogged, remove clog.
b.
If air supply is adequate (malfunction 32 above), replace
drain valve. Refer to paragraph 2-21.
c.
If problem still persists, notify your supervisor.
2-52