TM 10-3510-220-24
2-44.
DRYER TUMBLER ASSEMBLY (CONT)
ADJUSTMENT (Cont)
3.
Adjust fuel pump pressure.
NOTE
Power must be applied to the dryer, and the dryer and fuel pump must be operating,
before the fuel pump pressure can be adjusted.
a.
b.
c.
d.
Remove end cap (21) from adjusting
screw (22).
Turn adjusting screw (22) to adjust
pressure gauge (23).
Adjust fuel pressure for elevations as
follows:
Up to 3000 ft
120 psi
3000 ft. to 5000 ft
110 psi
5000 ft and up
100 psi
Install end can (21) on adjusting screw
(22).
Shut down dryer (Refer to TM
10-3510-220-10).
4.
Adjust burner electrodes and nozzle.
WARNING
Allow burner area to cool before any maintenance actions are performed on the
burner assembly. Personal injury could result if burner is hot.
WARNING
Fuel is toxic and flammable. Close fuel shutoff valve before performing any
maintenance actions on the burner assembly.
a.
Close dryer fuel shutoff valve by turning handle in a clockwise direction.
Change 4