TM 10-3510-220-24
2-44.
DRYER TUMBLER ASSEMBLY (CONT)
REPAIR (Cont)
j .
Install cover (42) on safety switch (45) and secure with four screws (41).
k .
Adjust safety switch (45). Refer to ADJUSTMENT paragraph for adjustment.
2. Replace thermometer.
WARNING
Serious burns can be caused by handling hot
items. The thermometer probe extends into the
lint exhaust duct and may be hot.
NOTE
Repair of the thermometer consists of removal
and replacement.
a. Remove thermometer (50) from exhaust
duct (51).
CAUTION
The probe on the gage can be damaged during
installation. Use care not to overtighten locknut.
b. Install thermometer (50) onto exhaust duct
(51).
3. Repair fuel solenoid.
WARNING
High voltage is present on this equipment. Do
not perform maintenance with power on. Death
or serious injury may result.
NOTE
Repair of fuel solenoid consists of removing the
old solenoid and replacing it with a new one.
a. Disconnect electrical power from the dryer.
2-157