TM 10-3510-220-24
2-52.
DRYER COMBUSTION BLOWER AND MOTOR ASSEMBLY (CONT)
INSTALLATION (Cont)
4. Tighten setscrew (16) and secure impeller
(13).
5. Align and install coupling (15) on the
impeller shaft. Tighten setscrew (14).
NOTE
12.
13.
14.
Install electrical cover (2) on the back of motor
(3) and secure with two screws (1).
Check for proper direction of rotation.
Perform follow-on installation.
Install tarp assembly (TM 10-3510-220-10).
It maybe necessary to turn the motor shaft by
hand to align the coupling and the fuel pump
shaft.
6. Align fuel pump coupling (15) with the fuel
pump shaft in blower housing (8). Insert
motor plate (7) and motor (3) into housing.
7. Secure motor plate (7) with lockwashers (6)
and bolts (5).
8. Loosen two setscrew (1) and remove electrical
cover (2) from the back of motor (3).
9. Position motor (3) in place and install four
lockwashers (10) and bolts (9).
10. Route the electrical wires into the motor and
install conduit (4) on motor (3).
11. Connect the electrical wires to the terminals
and connectors on the motor. Remove tags.
2-187