TM 10-3510-220-24
2-53. WATER PUMP AND MOTOR ASSEMBLY (CONT)
REPAIR (Cont)
a.
b.
c.
d.
Remove half coupling (11) and nipple (12)
from tee (13).
Remove plug (8), gasket (9), half coupling
(10), tee (13), and nipple (14) from pump (1).
NOTE
Use thread sealer compound (Item 5,
App C) when joining pipes and fittings.
Install plug (8), gasket (9), half coupling
(10), tee (13) and nipple (14) in pump (1).
Install nipple (12) and half coupling (11) in
tee (13).
WARNING
High voltage is present on this equip-
ment. Do not perform maintenance
with power on. Death or serious injury
may result.
2. Repair electrical plug, limit switch
receptacles, and limit switch by removing
and replacing them. Remove the receptacle
and limit switch as follows:
CAUTION
a.
Be careful not to damage gasket (15).
Remove six screws (17), switch box cover
(16), and gasket (15) from switch box (18).
Gasket will remain with cover or box until
wires have been disconnected.
2-190