TM 10-3510-220-24
2-53. WATER PUMP AND MOTOR ASSEMBLY (CONT)
REPAIR (Cont)
NOTE
Replace only components that
are defective.
3. Replace electrical fittings, conduit, or wiring
if defective. Repair or replace conduit if it is
not sealed against moisture.
a. Remove three screws (33) and loosen the
fourth screw. Turn cover plate (35) and
expose wires.
b. Disconnect wires on limit switch and/or
receptacle (refer to REPAIR paragraph 2,
steps a thru g.).
c.
d .
e.
f.
g.
h .
i.
j.
k.
Disconnect wire nut on same color wire at motor power junction box (36).
Tag and disconnect all wires in motor power junction box (36).
Remove locknut (32) on each end of conduit (34). Bend conduit and lift out. Remove four
wires from conduit.
Thread four wires through conduit (34) and insert conduit ends into switch box (18) and motor
power junction box (36).
Install locknuts (32) on each end of conduit (34).
Connect wires in switch box (18) (refer to REPAIR paragraph 2, steps h thru l.).
Connect wires in motor power junction box (36). Remove tags.
Position cover plate (35) on motor power junction box (36) and install three screws (33).
Tighten the fourth screw.
Check for proper direction of rotation.
2-192