TM 10-3510-220-24
3-15. EXTRACTOR ASSEMBLY (CONT)
REPAIR (Cont)
c.
Remove gyro ball cap (51) from the
top of gyro ball (52).
d.
Install new gyro ball cap (51) on
gyro ball (52) and tap into place
with plastic mallet. If the ball cap
does not easily fit in place, soak it in
warm water for a few minutes.
e.
Lubricate gyro ball (52). Refer to
LO 10-3510-220-12.
f.
Install extractor basket and lower
lid to operating position. (Refer to
step 2q above.)
5.
Remove and replace gyro ball (52).
WARNING
High voltage is present on this equipment.
Do not perform maintenance with power
on. Death or serious injury may result.
a.
Remove ball cap (51) from the top of
gyro ball (52). (Refer to step 4
above.)
b.
Use a block of wood and a hammer
and remove gyro ball (52) from the
shaft. Place the block under the
gyro ball and drive the ball from the
shaft.
3-62