3-16. EXTRACTOR DRIVE UNIT (CONT)
INSTALLATION
1.
Install center unit in extractor.
NOTE
Refer to matchmarks on base, trunnion
ring, and drive unit made instep 1 above
forproperpositioning of these parts in
relation to each other.
a.
Place trunnion ring (8) inside base
(13).
b.
Place three bumper caps (11) over
bumper rubbers (12) with raised lips
facing away from the center of the
extractor. Secure bumper caps with
six lockwashers (10) and bolts (9).
WARNING
The drive unit is heavy and maybe
awkward to handle. Use correct lifting
procedures, lifting devices, and/or
assistance from other personnel to avoid
injury.
c.
Place drive unit (7) inside trunnion
ring (8).
NOTE
If flat washers were located under
trunnion caps, install at this time in the
same location.
d.
Place two trunnion caps (5) over
trunnion rubbers (6) with raised lips
facing away from center of the
extractor. Secure with four
lockwashers (4) and bolts (3).
3-70