TM 10--3510--221--24
0145 00--3/4 blank
DRUM INLET VALVE REPLACEMENT -- Continued
0145 00
INSTALLATION
1. Apply anti--seizing tape to threads of elbows (4).
2. Install elbows (4) onto new actuator (16).
3. Position actuator (16) on mounting bracket (17) then secure with four screws (14) and lock washers (15).
NOTE
When installing valve body, flats on stem must be oriented with flats on actuator, otherwise valve will be
opened when it should be closed or visa--versa.
4. Rotate stem (18) on valve body (12) so that is aligned with flats (19) on actuator (16).
5. Install adapter (13) and valve body (12).
6. Insert flange (10) between bracket (11) and valve body (12).
7. Install, but do not tighten, two screws (8) and nuts (9).
8. Install, but do not tighten, two screws (6) and nuts (7).
9. Evenly tighten screws (6 and 8).
10. Connect tubes (3) to elbows (4) as tagged.
11. Perform a test laundry cycle (TM 10--3510--221--10). Visually check for water leaks while laundry cycle is
underway.
END OF WORK PACKAGE