TM 10--3510--221--24
0181 00--3/4 blank
FUEL SHUTOFF VALVE REPLACEMENT -- Continued
0181 00
INSTALLATION
1. Apply pipe thread sealant to threads of elbow (22) and adapter (25) or elbows (23 and 27).
2. Thread elbow (22) and adapter (25) or elbows (23 and (27) into new solenoid valve (15).
3. Thread nipple (29) and two conduit nuts (30) onto solenoid valve (15).
4. Position solenoid valve (15) onto outlet box (18), then secure with conduit nuts (28 and 30).
5. Connect fuel tube (24) at adapter (25) or fuel tube (26) at elbow (27).
6. Connect fuel tube (21) at elbows (22 and 23).
7. Insert wires of solenoid valve (15) through conduit (20), then into outlet body(14).
8. Insert conduit (20) into outlet box (18) then secure with conduit nut (19).
9. Position cover (17) onto outlet box (18), then secure with two screws (16).
10. Connect wires of solenoid valve (15) as tagged.
11. Position cover (12) and gasket (13) onto outlet body (14), then secure with two screws (11).
12. Position cover (10) onto air box (6), then secure with six nuts (7), lock washers (8) and flat washers (9).
13. Connect fuel hoses (1 and 2) to quick--connect fittings (3 and 4).
14. Use maintenance menu to test heating system (WP 0010 00). While heating system is operating visually
check for fuel leaks.
15. Slide air inlet screen (5) into air box (6) with direction arrow (31) pointing towards heater inlet.
END OF WORK PACKAGE