TM 10--3510--221--24
0204 00--2
PRODUCT PRESSURE SENSOR
REPLACEMENT -- Continued
0204 00
3
4
8
7
6
5
INSTALLATION
1. Apply anti--seizing tape to threads of new pressure sensor (7).
2. Thread pressure sensor (7) into elbow (8).
3. Connect electrical connector (6) to pressure sensor(7), then secure by tightening screw (5).
4. Access pressure sensor calibration function using maintenance menu (WP 0010 00), then set output of sensor
PT501 to 0 psig.
5. Open manual valve (3).
6. Use maintenance menu to test air system. After air system is pressurized audibly check for air leaks.
7. Close access door (2) and secure by engaging two latches (1).
END OF WORK PACKAGE