TM 10--3510--221--24
0222 00--1
AIR COMPRESSOR INVERTER REPLACEMENT
0222 00
THIS WORK PACKAGE COVERS:
Removal, Installation
INITIAL SETUP:
Maintenance Level
Materials/Parts
Unit
Tools and Special Tools
Equipment Conditions
Tool Kit, General Mechanics (Item 1, WP 0272 00)
LADS power must be shut off and door opened at
Multimeter (Item 2, WP 0272 00)
main control enclosure (WP 0112 00).
REMOVAL
WARNING
The inverter drive must discharge before it is safe to disconnect wire connections. DEATH
ON CONTACT may result if personnel fail to observe this safety precaution.
1. Loosen captive screw (1), then remove cover (2) from inverter drive (3).
2. Verify CRG indicator (4) is off and use a multimeter to verify voltage is not present at terminal strip (5).
3. Unplug display PCB (6) from inverter drive (3).
4. Tag and disconnect wiring at connector (7).
5. Pull control wiring out of cover (2).
6. Tag and disconnect wiring at terminal strip (5).
7. Remove two screws (8) and nuts (9), then remove inverter drive (3) from door (10).