TM 10-3510-222-243-30.CONTROLPANEL-continued.(5) DIMMER (18).(a)Remove twelve screws (1) from cover (2) and remove cover (2).(b)Tag and remove electrical wiring from DIMMER (18).(c)Remove nut (16) and flat washer (22) from DIMMER (18) and remove DIMMER.(d)Position new DIMMER (18) on control panel (3) and install nut (16) and flat washer (22).NOTEWire numbers are stamped on each electrical wire. This information, in conjunction with data onFO-2 Washer Wiring Diagram, may be used to connect wires if tags are lost or illegible.(e)Connect electrical wiring as tagged.(f)Position cover (2) on control panel box and install twelve screws (1).(6)MANUAL TIMER (19).(a)Remove twelve screws (1) from cover (2) and remove cover (2).(b)Tag and remove electrical wiring from MANUAL TIMER (19).(c)Remove two screws (21), bracket (20) and MANUAL TIMER (19).(d)Position new MANUAL TIMER (19) on control panel (3) and install bracket (20) and two screws(21).NOTEWire numbers are stamped on each electrical wire. This information, in conjunction with data onFO-2 Washer Wiring Diagram, may be used to connect wires if tags are lost or illegible.(e)Connect electrical wiring as tagged.(f)Position cover (2) on control panel (3) and install twelve screws (1).c. INSTALLATION(1)Install control panel (3).(2)Install four screws (4) and washers (5).(3)Install adhesive (RTV) around control panel (3).NOTEWire numbers are stamped on each electrical wire. This information, in conjunction with data onFO-2 Washer Wiring Diagram, may be used to connect wires if tags are lost or illegible.(4)Connect wiring as tagged.(5)Install twelve screws (1) on cover (2).3-69