TM 10-3510-222-24
3-78. DRYER CONDUITS - continued.
b.
REPAIR
Repair consists of replacing damaged and/or missing components of the dryer conduits.
c.
INSTALLATION
(1)
Tumbler Motor Base Control Box Conduit. (Figure 3-78)
(a)
Position gasket (3) on adapter (2).
(b)
Feed wires into control panel and install nut (1).
NOTE
Wire numbers are stamped on each electrical wire. This information, in conjunction with data on
FO-4 Dryer Wiring Diagram, may be used to connect wires if tags are lost or illegible.
(c)
Connect wires to relay (10) as tagged.
(d)
Position gasket (8) on adapter (7), feed wires into tumbler motor (9) and install locknut (6).
(e)
Connect wires to tumbler motor (9) as tagged.
(f)
Install cover (5) and secure with two screws (4).
(2)
Transformer Box - Control Box Conduit.
(a)
Install conduit (13) to the transformer box (Para 2-56).
(b)
Position gasket (12) on adapter (11), feed wires through conduit (13) into control box (14).
(c)
Install nut (10).
NOTE
Wire numbers are stamped on each electrical wire. This information, in conjunction with data on
FO-4 Dryer Wiring Diagram, may be used to connect wires if tags are lost or illegible.
(d)
Connect wires (8) to terminal board (9) as tagged and secure with screws (7).
(e)
Connect wires (5) to motor starter (6) as tagged and secure with screws (4).
(f)
Connect wires (2) to terminal box (3) as tagged and secure with screws (1).
3-185