DIRECT SUPPORT AND GENERAL SUPPORT
MAINTENANCE INSTRUCTIONS
Section I. REPAIR PARTS, SPECIAL TOOLS, AND EQUIPMENT
Tools, equipment and repair parts issued with or authorized for the bath unit are listed in the Basic Issue Items List,
5-2. Special Tools and Equipment
No special tools or equipment are required by Direct or General Support Maintenance personnel.
5-3. Maintenance
Repair Parts
Repair parts and equipment for direct support and general support maintenance for the bath unit are found in TM 10-
4510-201-24P.
Section II. DIRECT AND GENERAL SUPPORT TROUBLESHOOTING
For a general description and purpose of the troubleshooting table, refer to paragraph 3-3.
5-5. Direct and General
Support Troubleshooting
Table 5-1 lists the bath unit troubleshooting malfunctions and is as
follows:
MALFUNCTION
TEST OR INSPECTION
CORRECTIVE ACTION
WATER HEATER ASSEMBLY
1. WATER TEMPERATURE TOO HIGH OR TOO LOW
Step 1. Check to see if water pressure and temperature control is out of adjustment.
2. FUEL PUMP NOT FUNCTIONING PROPERLY
Step 1. Check for defective fuel pump.
3. FUEL PRESSURE ERRATIC
Step 1. Piston in fuel pump defective.
4. MOTOR NOISY DURING OPERATION
Step 1. Check for noisy or worn bearings.
5. MOTOR DOES NOT OPERATE-
Step 1. Check for shorted rotor.
Step 2. Check for open or shorted windings.
Section III. GENERAL MAINTENANCE INSTRUCTIONS
a. This section provides general cleaning, inspection and repair instructions that are common to components used
on the bath unit.
b. Special cleaning, inspection and repair instructions applicable to any individual component are covered with that
component in the applicable sections of this manual.