TM 10-4510-207-14
5.3. PUMP ASSEMBLY FRAME REPLACEMENT.
This task covers: a. Disassembly b. Assembly
INITIAL SETUP
Tools:
General Safety Instructions:
General Mechanics Tool Set (Appendix B, Section III,
WARNING
Item 1).
High voltage is used in the portable shower
Materials/Parts:
module. Care must be taken to avoid personal
injury or death from energized circuits.
NOTE
Repair of the pump assembly frame requires removal of all
components.
b.
Disassembly.
(7) Remove six screws (1) and mounting plate (2) with instruction plate (3) attached.
NOTE
The instruction plate has adhesive backing and is secured to the
mounting plate. If the instruction plate is removed, it cannot be
used again and must be replaced.
(8) If instruction plate (3) needs to be replaced, remove it form the mounting plate (2). If the mounting plate
needs to be replaced, discard both.
(9) Send pump assemble frame (4) to general support maintenance for repair.
5-11