  • Download PDF
  • Order CD-ROM
  • Order in Print
OPERATOR MAINTENANCE MILITARY MOUNTAINEERING KITS ­ ICE SCREW REPAIR
Dry the cams thoroughly; then lubricate IAW WP 0026.

OPERATOR MANUAL FOR MILITARY MOUNTAINEERING KITS
Page Navigation
  68    69    70    71    72  73  74    75    76    77    78  
img
. . . . .
TM 10-8465-237-10
0019
OPERATOR MAINTENANCE
MILITARY MOUNTAINEERING KITS CAMMING DEVICE
CLEANING
INITIAL SETUP:
Personnel Required
Tools
Mountaineer (1)
Brush, File Cleaner (WP 0029, Item 1)
Gloves, Men s and Women s (WP 0029, Item
2)
Equipment Condition
References
Clean and dry
WP 0026
CLEANING
WARNING
Be careful to avoid scalding injury from hot water. Use hand protection. Failure to comply with
this warning may lead to injury to personnel.
NOTE
Depending upon how dirty your cams are and what lubricants have been used in the
past, they may require several cleanings to work all the dirt and old lube out from the
axle. Failure to comply may lead to damage to equipment.
1.
Heat water in a pan until it is near the boiling point.
2.
Swish the cam head (Figure 1) in hot water, while working the trigger bar (Figure 1), being very
careful to avoid burns.
CAM HEAD
TRIGGER BAR
Figure 1. Camming Device.