TM 10-3510-209-24
3-18. EXTRACTOR CONTROL BOX (CONT)
REPAIR
1.
Remove and replace lid safety switch and/or solenoid safety switch,
WARNING
High voltage is present on this equipment. Do not perform maintenance with
power on. Death or serious injury may result.
WARNING
Failure to adjust the lid safety switch and/or solenoid safety switch could result in
injury to personnel.
a.
Set extractor circuit breaker to the OFF position.
b.
Remove twelve screws (1), lockwashers
(2), and extractor control panel cover (3).
NOTE
A record of wire removal is needed
so that installation of wires on the
replacement
switch
is
exactly
duplicated.
c.
Tag and disconnect electrical wires (17)
from lid safety switch (19).
d.
Remove two screws (10) and lid safety
switch (19).
e.
Install lid safety switch (19) and two
screws (10).
f.
Connect wires (17) to lid safety switch
(19). Remove tags.
g.
Refer to ADJUSTMENT, step 2, and
adjust lid safety switch (19).
h.
Install twelve screws (1), lockwashers (2),
and extractor control panel cover (3).
3-81