TM 10-3510-209-24
3-18. EXTRACTOR CONTROL BOX (CONT)
REPAIR (Cont)
i.
Set extractor circuit breaker to the ON position.
2.
Remove and replace timer control.
WARNING
High voltage is present on this equipment. Do not perform maintenance with
power on. Death or serious injury may result.
a.
Set extractor circuit breaker to the OFF position.
b.
Loosen screw (18) on timer (19).
c.
Lift locking clamp (20) to horizontal position.
d.
Slide timer (19) and gasket (21) outward and remove it from its housing.
e.
Insert new timer (19) and gasket (21).
f.
Push locking clamp (20) down to vertical position.
g.
Tighten screw (18).
h.
Set extractor circuit breaker to the ON position.
NOTE
FOLLOW-ON-MAINTENANCE:
Install sound deadening panel (para 2-17).
Install tarp assembly (TM 10-3510-209-10).
3-82