TM 10-3510-220-24
3-24. DRYER ELECTRIC CONTROL ASSEMBLY (CONT)
REMOVAL (Cont)
b.
Remove three thumbscrews and open
dryer electrical panel cover (10) and
remove plastic wire ties as required.
c.
Tag and disconnect four wires (11) from
electrical panel (12).
d.
Remove four nuts (13), lockwashers (14),
conduit nut (15), and timer (16) from dryer.
e.
Remove conduit (17) from the base of
timer (16).
INSTALLATION
1.
Install thermoswitch control assembly.
WARNING
High voltage is present on this equipment.
Do not perform maintenance with power on.
Death or serious injury may result.
a.
b.
c.
d.
e.
f.
Install thermoswitch (9) on the dryer.
Route wires (5) through conduit (7) and
install the conduit on thermoswitch (9).
Install conduit connector (8) on the
electrical connector box (3).
Connect wires (5) to terminals and con-
nectors in electrical connector box (3).
Remove tags.
Install plastic wire ties (Item 11, App C)
as required.
Position cover (2) on electrical connector
box (3) on dryer blower motor (4) and
secure with two screws (1).
3-112