TM 10-3510-220-24
3-24. DRYER ELECTRICAL CONTROL ASSEMBLY (CONT)
INSTALLATION (Cont)
2.
Install dryer timer.
a.
Route four wires (11) of replacement timer
(16) through conduit (17) and to electrical
panel (12).
b.
Secure the conduit (17) on the base of
timer (16). Install conduit nut (15) on
inside of control box.
c.
Install timer (16), four nuts (13), and
lockwashers (14) on the dryer.
d.
Connect wires (11) on electrical
panel (12). Remove tags.
e.
Install plastic wire ties (Item 11,
App C) as required.
f.
Close dryer electrical panel cover
(10) on electrical panel (12).
3.
Perform follow-on installation. Install tarp
assembly and platform (TM 10-3510-220-10).
3-113