TM 10-3510-220-24
3-25. DRYER UVSCANNERAND FLAME SAFEGUARD ASSEMBLY (CONT)
TEST (Cont)
5.
6.
7.
8.
9.
Remove three screws (3), lockwashers (4),
flatwashers (5) and cover plate (6).
CAUTION
Ensure that power is off before making
continuity check. Damage to test equipment
could result.
Use a multimeter and check continuity
from input terminals to output terminals on
motor contactor solenoid (7). Meter should
indicate open circuit at each set of terminals.
Push upon motor contactor solenoid. Meter
should indicate continuity at each set of terminals.
Loosen screw (8) and remove cover (9) on flame safe-
guard control.
WARNING
Remove rings, bracelets, wristwatches, and
neck chains before working around or on the
laundry unit. Jewelry can catch on
equipment and cause injury, or may short
across an electrical circuit and cause severe
burns or electrical shock.
WARNING
Use extreme caution when performing the
following test with power ON.
Push dryer start switch and check for 120 V ac at test
points (12) and (11) with multimeter. If voltage is not
normal, test for 120 V ac input to dryer (appendix E,
figure 4). If voltage is normal, go to next step.
Push dryer stop switch and remove two screws
(10) and flame safeguard control circuit card (13).
3-115