TM 10--3510--221--10
0019 00--3
WATER RECYCLE SYSTEM TROUBLESHOOTING --
Continued
0019 00
STANDPIPE LEVEL LO OR STILL NOT FILLING -- Continued
2.
Check for water leakage at still door gaskets.
Is water leaking from gasket(s)
YES Replace still door gasket(s) (WP 0036 00).
NO Go to step 3.
3.
Check petcock on housing of distillate pump.
Is petcock open?
YES Close petcock. Return to normal operation.
NO Go to step 4.
4.
Check all condensate hose connections for signs of leakage.
Are any leaks found?
YES Repair as necessary or notify maintenance.
NO Notify maintenance.
STANDPIPE NOT EMPTYING
NOTE
During high speed extracts water bouncing around inside standpipe may get high enough to
cause a STANDPIPE NOT EMPTYING failure message. In this case the message will
disappear within 30 seconds after the extract is completed and no operator action will be
necessary.
1.
Use EXAMINE INPUTS mode to observe reading for LT201 (standpipe level).
Is reading > 24 inches?
YES Go to step 3.
NO Go to step 2.
2.
Continue to observe LT201 reading for approximately five minutes.
Does reading drop to 3 inches at least once?
YES Return to normal operation.
NO Go to step 3.
3.
Check for water flowing from standpipe overflow hose.
Is water flowing from overflow hose?
YES Go to step 4.
NO Return to normal operation.
4.
Check for clogged cartridge in coalescing filter (WP 0035 00).
Is coalescer cartridge clogged?
YES Replace coalescer cartridge. Return to normal operation.
NO Reinstall coalescer cartridge. Go to step 5.