TM 10--3510--221--10
0019 00--1
WATER RECYCLE SYSTEM TROUBLESHOOTING
0019 00
THIS WORK PACKAGE COVERS:
Troubleshooting Observed or Displayed Faults on Water Recycle System
INITIAL SETUP:
Maintenance Level
Materials/Parts
Operator
ANTI--FOAM SUPPLY NO FLOW
1.
Check anti--foam supply container.
Is anti--foam container empty?
YES Replenish anti--foam supply (WP 0009 00). Return to normal operation.
NO Go to step 2.
2.
Check pickup tube inserted into anti--foam container.
Is tube inserted far enough into anti--foam container?
YES Go to step 3.
NO Properly insert pickup tube. Return to normal operation.
3.
Remove pickup tube inserted into ant--foam container.
4.
Check for clumps of anti--foam or dried anti--foam blocking screen on end of pickup tube.
Is screen blocked with anti--foam?
YES Flush anti--foam clumps from screen with water. Return to normal operation.
NO Go to step 5.
5.
Check entire length of anti--foam tube for kinks.
Is tube kinked?
YES Remove kink(s) from tube. Return to normal operation.
NO Continue laundry cycle(s) adding anti--foam through hand pump connected to still
(WP 0013 00). When laundry cycles are completed notify maintenance.
CONDENSATE TEMPERATURE HI
1.
Perform a cooldown cycle then shutdown LADS (WP 0010 00).
2.
Check for debris on heat exchanger inlet screens (WP 0030 00).
Are inlet screens clear?
YES Go to step 3.
NO Remove debris from inlet screens. Return to normal operation.