TM 10--3510--221--10
0019 00--2
WATER RECYCLE SYSTEM TROUBLESHOOTING --
Continued
0019 00
CONDENSATE TEMPERATURE HI -- Continued
3.
Remove inlet screens and check for debris on heat exchangers (WP 0024 00).
Are heat exchangers clear?
YES Go to step 3.
NO Remove debris from heat exchangers. Return to normal operation.
4.
Check for debris on still condenser fan guard (WP 0024 00).
Is fan guard clear?
YES Notify maintenance.
NO Remove debris from fan guard. Return to normal operation.
RECYCLED WATER TEMPERATURE HIGH
1.
Perform cooldown cycle then shutdown LADS (WP 0010 00).
2.
Check for debris on subcooler inlet screen (WP 0031 00).
Is inlet screen clear?
YES Go to step 3.
NO Remove debris from inlet screen. Return to normal operation.
3.
Remove inlet screen and check for debris on subcooler (WP 0024 00).
Is subcooler clear?
YES Go to step 4.
NO Remove debris from subcooler. Return to normal operation.
4.
Check for debris on evaporative cooler inlet filters (WP 0032 00).
Are inlet filters clear?
YES Go to step 5.
NO Remove debris from inlet filters. Return to normal operation.
5.
Remove inlet filters and check for debris on demister mesh (WP 0033 00).
Is demister mesh clear?
YES Continue laundry cycle(s). When laundry cycles are completed notify maintenance.
NO Remove debris from demister mesh. Return to normal operation.
STANDPIPE LEVEL LO OR STILL NOT FILLING
1.
Check drain valves on bottom of still.
Are drain valves open?
YES Close drain valves. Return to normal operation.
NO Go to step 2.