TM 10--3510--221--10
0018 00--9
WASHING/DRYING SYSTEM TROUBLESHOOTING --
Continued
0018 00
R2 TANK NOT HEATING
1.
Check drain valves on bottom of still.
Are drain valves open?
YES Close drain valves. Return to initial settings, before use, and self tests (WP 0009 00).
NO Go to step 2.
2.
Check for water leakage at still door gaskets.
Is water leaking from gasket(s)
YES Replace still door gasket(s) (WP 0035 00).
NO Notify maintenance.
3.
Using EXAMINE INPUTS mode observe reading for TE300 (thermal fluid temperature).
Is reading >250 degrees F?
YES Go to step 4.
NO Go to HEATING SYSTEM FAILURE FAULT (WP 0020 00).
4.
At operator panel A use MENU SELECTION switch (WP 0008 00, Figure 2, 9) to select OVERRIDE
HEATING
5.
Perform laundry operations on loads better suited for current temperature and allow water to
heat--up to desired temperature.
Does R2 WATER TEMP increase to desired temperature after 3 or less cycles.
YES Return to normal operation.
NO Perform laundry operations as necessary then notify maintenance.
R2 WATER TEMPERATURE HI OR LO
1.
Using EXAMINE INPUTS mode observe reading for TE103 R2 tank water temperature.
Is temperature displayed higher than selected temperature?
YES Go to step 2.
NO Go to step 3.
2.
Perform laundry operations on loads better suited for current temperature while and allow water to
cooldown to desired temperature.
Does R2 WATER TEMP HI fault disappear after 3 or less cycles.
YES Return to normal operation.
NO Go to RECYCLED WATER TEMPERATURE HIGH FAULT (WP 0019 00).
3.
Perform laundry operations on loads better suited for current temperature while and allow water to
heat up to desired temperature.
Does R2 WATER TEMP LO fault disappear after 3 or less cycles.
YES Return to normal operation.
NO Perform laundry operations as necessary then notify maintenance.