TM 10--3510--221--24
0207 00--1
ORIFICE MANIFOLD REPLACEMENT
0207 00
THIS WORK PACKAGE COVERS:
Removal, Installation
INITIAL SETUP:
Maintenance Level
Materials/Parts
Unit
Tags (Item 9, WP 0271 00)
Tools and Special Tools
Equipment Conditions
Tool Kit, General Mechanics (Item 1, WP 0272 00)
LADS power shut off at main control
enclosure (WP 0112 00).
REMOVAL
1. Disengage two latches (1), then open access door (2).
2. Close manual valve (3).
3. Open petcock (4), allow product air to vent, then close petcock.
4. Disconnect tube (5) from connector (6).
5. Tag and disconnect tubes (7) from eight tees (8).
6. Remove two screws (9), flat washers (10), and nuts (11), then remove orifice manifold (12) from frame (13).
7. Remove two clamps (14) from orifice manifold (12).
1
2