TM 10-3510-222-10
Table 3-1. Troubleshooting - continued.
MALFUNCTION
TEST OR INSPECTION
CORRECTIVE ACTION
5.
DRYER FAILS TO DRY LAUNDRY continued.
CAUTION
When installing UV scanner safeguard flame control, do not overtighten or it will crack.
d.
Install UV Scanner safeguard flame control into sighteye.
e.
On START button, push START.
f.
If dryer fails to dry laundry, push STOP RESET button.
Step 3.
Check for clogged fuel filter.
a.
On STOP RESET button, push STOP.
b.
On fuel filter, turn tee handle on top of filter four times to clean.
c.
On START button, push START.
d.
If fuel pressure is low, pulsates, or there is no pressure, push STOP RESET button and notify unit
maintenance.
6.
EXTRACTOR FAILS TO START.
Step 1.
Check EMERGENCY STOP ONLY button.
a.
If EMERGENCY STOP ONLY button is pushed in, reset by pulling EMERGENCY STOP ONLY
button out.
b.
Press PUSH TO START button.
Step 2.
Check lid and make sure it is closed.
a.
If lid is open, close lid all the way down on the seal.
b.
Press PUSH TO START button.
3-6