TM 10-3510-222-10
Table 3-1. Troubleshooting - continued.
MALFUNCTION
TEST OR INSPECTION
CORRECTIVE ACTION
4.
DRYER FAILS TO START - continued.
f. On UV scanner control box terminal box relay, push UV scanner control terminal box
reset button.
g. Close control box cover.
h. Push START button.
i. If dryer fails to start, push STOP RESET button and notify unit maintenance.
5. DRYER FAILS TO DRY LAUNDRY.
WARNING
Fuel is flammable and can explode easily. To avoid serious injury or death, keep fuel away from
open fire or hot dryer parts.
Step 1.
Check if UV Scanner control terminal box is tripped.
a.
On STOP RESET button, push STOP.
b.
Open control box cover.
c.
Push UV Scanner control terminal box reset.
d.
Close control box cover.
e.
On START button, push START.
Step 2.
Check UV Scanner safeguard flame control for cleanliness/cracks.
a.
On STOP RESET button, push STOP.
b.
Unscrew UV Scanner safeguard flame control on front of dryer and remove.
c.
Clean UV Scanner safeguard flame control with a dry clean cloth and check for cracks.
3-5