TM 10-3510-222-10
Table 3-1. Troubleshooting - continued.
MALFUNCTION
TEST OR INSPECTION
CORRECTIVE ACTION
6.
EXTRACTOR FAILS TO START continued.
Step 3.
Check for electrical power.
a.
Open power distribution panel and see if extractor number 2 circuit breaker has tripped. If tripped,
reset circuit breaker.
b.
Close power distribution panel.
c.
Press PUSH TO START button.
Step 4.
Check RESET button.
a.
Press RESET button to make sure button is reset.
b.
Press PUSH TO START button.
Step 5.
Check timer interval for correct setting.
a.
Set timer interval to three minutes.
b.
Press PUSH TO START button.
c.
If extractor fails to start, notify unit maintenance.
7.
EXTRACTOR FAILS TO DRAIN.
Inspect drain hose/piping for clogged condition.
a.
Remove drain hose.
b.
If hose is clogged, remove clog.
c.
Install drain hose.
d.
If piping is clogged, remove clog.
e.
Press PUSH TO START button. If extractor fails to drain, push EMERGENCY STOP ONLY button
and notify unit maintenance.
3-7