TM 10-3510-224-13&P
0009 00
Table 1. Preventive Maintenance Checks and Services for the CSSL-Continued.
0009 00-5
Item
No.
Interval
Item to be
checked or
serviced
Procedure
Equipment not ready/available if:
13
During
Vent Fan
If vent fan (10) fails during operation,
cycle the switch. If no response, notify
Unit Maintenance.
Vent Fan inoperative or noisy.
14
During
Space Heater
If heater (11) fails during operation, rotate
the heater control knob (12) fully in both
directions. If no response, notify Unit
Maintenance.
Space Heater inoperative.
15
During
Power Entry
Connectors
If power fails during operation, check for
physical damage to the power entry panel
(17). Ensure that the cables are properly
connected (refer to WP 0005 00). If
connections appear secure and there is
still no power, notify Unit Maintenance.
Damaged power entry panel or connectors.
Improper connections.
16
During
CSSL Modified
End Section
In adverse weather conditions check the
securing straps (16). Check for torn or
otherwise damaged fabric.
Torn fabric, loose straps, missing or damaged
hardware.
WARNING
Do not touch damaged circuit breakers.
Notify Direct Support Maintenance.
17
During
Circuit Breakers
If a circuit breaker trips during operation,
open the circuit breaker panel (17) and
examine the circuit breakers. Note any
damage to the breakers and the panel. If
no damage is noted, activate the
breakers to determine if they function
properly. If the breaker trips again, notify
Unit Maintenance.
Damaged or non-functioning circuit breakers.
18
During
Exterior GFCI
Receptacle
If power from the GFCI receptacle fails,
set the main circuit breaker (#10) in the
left side power distribution panel, to ON.
Set circuit breaker #17 to ON and test the
GFCI receptacle on the power entry panel
on the utility wall (18) by pushing the
TEST button. If the indicator light does
not activate, push the RESET button.
Repeat the test. If the receptacle does not
work, notify Unit Maintenance.
Damaged or non-functioning exterior GFCI
receptacle.