TM 10-7360-226-13&P
0006 00
CONTAINERIZED KITCHEN (WITH TRAILER)
OPERATION UNDER USUAL CONDITIONS
WARNING
Do NOT use one of the water supply hoses to drain the tray pack heater.
They are for potable water use and could become contaminated.
3. If the tray pack heater must be drained, roll it to the area of the personnel access door, open its
drain valve, and drain the water into the floor drain. Close the valve when draining is complete.
Pack the heater fan assembly inside the tray pack heater.
4. If necessary, disconnect the external drain hose and drain it. Tightly coil the hose and pack it
on the lower shelf of the sink assembly.
5. Position the tray pack heater as shown earlier in Figure 15, with its back to the mechanical
room wall. Place the base rack inside the burner rack and set both on top of the heater.
6. Place two ratchet straps over these items, running from the loops on the mechanical room wall
down to the tie-down provisions in the floor. Tighten the straps securely.
Oven Assembly
1. Pack the MBU in place with its fuel and power lines connected.
2. Unplug the oven's 24 VDC and 120 VAC power cables from the ceiling raceway. Coil the 120
VAC cable and lay it on top of the oven. Coil the 24 VDC cable, along with the fuel line and
power cable to the tray pack heater, and pack them between the MBU and the left side of the
oven base.
3. Move the pan rack out of the way and disconnect the fuel line from its outlet at the mechanical
room wall. Install the dust plugs. Coil the hose and pack it between the MBU and the right
side of the oven base.
4. Pull the oven assembly away from the fabric wall far enough to remove the chimney pipe.
Remove the pipe and stow it in one of work table drawers inside the oven.
5. Hook the long section of two ratchet straps to the same floor tie-down provisions used for the
tray pack heater, and temporarily drape the straps over the heater.
6. Position the oven assembly as shown earlier in Figure 15, with its back toward the cook center,
and strap it down with the two ratchet straps run from side to side. Run the straps under the
oven fan assembly, not over the top of it.
Change 2
0006 00-30