TM 10-3510-209-24
2-21.1. WASHER FLOAT LEVEL ASSEMBLY (CONT)
REPAIR
Repair by replacing defective component(s).
ASSEMBLY
1.
Install float rod (55) in float chamber (60).
2.
Install float switch assembly (15) on float rod (55).
3.
Install screw (52), lock washer (51), and hex nut (50) on float switch assembly (15) and float chamber clamp (54).
4.
Install low-level speednut (49) on float rod (55).
INSTALLATION
1.
Install float chamber (60) on washer assembly (6).
2.
Install four bolts (58), washers (57) and nuts (56) on brackets (59).
3.
Install electrical cable (18) in float switch (15). Install nut (17) and secure electrical cable. Connect wires (16) to
float switch (15). Remove tags.
4.
Install cover (14) and screw (13) on float switch (15).
5.
Install tube (8) and clamp (7) on float chamber (60).
ADJUSTMENT
Refer to paragraph 2-20 for adjustment.
NOTE
FOLLOW-ON MAINTENANCE: Washer drivebelt cover installed (para 2-22).
Water pump installed (TM 10-3510-209-10).
Change 1 2-84.1