TM 10-3510-209-24
3-16. EXTRACTOR ASSEMBLY (CONT)
REPAIR (Cont)
WARNING
Components of the extractor are
heavy and may be awkward to
handle.
Use
correct
lifting
procedures, lifting devices, and/or
assistance from other personnel to
avoid injury.
NOTE
Lubricate
gyro
ball
(45)
in
accordance with LO 10-3510-209-12.
q.
Refer to REPAIR, step lm, and install
basket in extractor.
r.
Connect extractor drain line. Refer to
TM 10-3510-209-10.
s.
Lower extractor lid to operating position.
3.
Test extractor. Refer to TM 10-3510-209-10.
4.
Remove and replace gyro ball cap.
WARNING
High voltage is present on this
equipment.
Do
not
perform
maintenance with power on. Death
or serious injury may result.
a.
Set extractor circuit breaker on electrical
power panel to the OFF position.
b.
Open extractor lid. Remove basket.
3-65