2-45. DRYER ELECTRICAL CONTROL ASSEMBLY (CONT)
SERVICE
WARNING
High voltage is present on this equipment. Do
not perform maintenance with power on. Death
or serious injury may result.
1. Remove three thumbscrews (2) and open control
box(l).
WARNING
Compressed air used for cleaning
purposes will not exceed 30 psi
(207 kPa). Use only with effective
chip-guarding and personal-protec-
tive equipment (goggles, shield,
gloves, etc.).
2. Clean electrical components with
compressed air.
3. Close control box door (1) and
secure with thumbscrews (2).
4. Perform follow-on installation.
Install tarp assembly
(TM 10-3510-220-10).
ADJUST
Adjust operating temperature control (3). Turn
knob from O to 250 degrees and check pointer
calibration. Adjust position by loosening setscrew
and moving knob to correct position.
Tighten
setscrew.
2-162