TM 10--3510--221--10
0018 00--5
WASHING/DRYING SYSTEM TROUBLESHOOTING --
Continued
0018 00
DRYER A or B INLET TEMP HI/LO or LAUNDRY NOT DRYING -- Continued
5.
Check drying temperature used versus drying instructions for laundry load.
Was correct drying temperature used?
YES Go to step 6.
NO Repeat laundry cycle with proper drying temperature.
6.
At operator panel where cycle was paused press MENU SELECTION switch (7) to CONTINUE
CYCLE.
Does dryer blower come on?
YES PAUSE cycle. Go to step 11.
NO Go to step 7.
WARNING
High voltage is present in main control enclosure. Use extreme caution when working inside. Never
place hands or tools on exposed wire connections. Death on contact may result if personnel fail to
observe this safety precaution.
7.
Open door on main control enclosure.
8.
Observe position of circuit breaker CB2 (Figure 1, 8).
Is circuit breaker ON?
YES Notify Maintenance.
NO Go to step 9.
9.
Position circuit breaker to ON then close and secure door.
10. At operator panel where cycle was paused press MENU SELECTION switch (Figure 2, 7) to
CONTINUE CYCLE.
Does dryer blower come on?
YES Return to normal operation.
NO Notify Maintenance.
11. Check for debris in water pump strainer (WP 0028 00).
Is strainer clean?
YES Go to step 12.
NO Clean and replace strainer. Return to normal operation.
12. Check for debris at drain port in bottom of washing/drying drum.
Is drain port blocked?
YES Remove blockage as necessary. Return to normal operation.
NO Run drying cycle to complete current load then notify maintenance.