TM 10--3510--221--10
0018 00--8
WASHING/DRYING SYSTEM TROUBLESHOOTING --
Continued
0018 00
R2 TANK NOT FILLING
1.
Determine if problem occurred during initial filling or during normal operation.
Did problem occur during initial filling?
YES Go R1 or WASH TANK(S) NOT FILLING FAULT.
NO Go to step 2.
2.
Check petcock on housing of distillate pump.
Is petcock open?
YES Close petcock. Return to normal operation.
NO Go to step 3.
3.
Check petcock on bottom of coalescer.
Is petcock open?
YES Close petcock. Return to normal operation.
NO Go to step 4.
4.
Check petcocks on subcooler.
Are petcock(s) open?
YES Close petcock(s). Return to normal operation.
NO Go to step 5.
5.
Check drain valves on bottom of still.
Are drain valves open?
YES Close drain valves. Return to normal operation.
NO Go to step 6.
6.
Check all condensate hose connections for signs of leakage.
Are any leaks found?
YES Repair as necessary or notify maintenance.
NO Notify maintenance.